Hydropower Oil & Grease Analysis
Identifying contamination, lubricant deterioration and early signs of equipment wear

Why lubricant testing matters
Hydropower equipment operates for extended periods under varying loads, temperatures and environmental conditions. Hydraulic oil, gearbox oil and bearing grease are essential to reliable operation, yet their condition cannot always be assessed by appearance alone. Routine sampling and laboratory analysis during planned service inspections can reveal developing issues before they lead to costly repairs or unplanned generation losses.
Three critical areas of analysis
Hydraulic oil
Testing can assess particle contamination, water content, viscosity and fluid degradation. Poor cleanliness may accelerate wear of pumps, valves and actuators, affecting hydraulic response and reliability.
Gearbox oil
Analysis can identify wear metals, water ingress, viscosity changes and oxidation. Trending results helps highlight developing gear or bearing wear and supports informed oil-change decisions.
Bearing grease
Grease analysis, where a representative sample can be obtained, can indicate water or particulate contamination, lubricant condition and metallic wear debris associated with bearing deterioration.
What the results tell us
Laboratory findings are assessed against the lubricant specification, equipment requirements and, where available, previous sample results. Trending is particularly valuable: a change in contamination or wear-metal levels may be more informative than a single isolated result. Recommendations may include closer monitoring, filtration, oil replacement, investigation of water ingress or further mechanical inspection.

Our approach during service inspections
Hydro Maintain incorporates lubricant condition checks and, where included in the agreed service scope, representative sampling for specialist analysis into routine hydropower maintenance visits. Samples are identified by asset and sampling point, and findings are reviewed alongside operating history, visual inspections and other condition-monitoring information. This provides a practical basis for prioritising maintenance and planning remedial works.
The benefit of preventative maintenance
Early detection can help reduce the likelihood of unexpected breakdowns, extend component service life, avoid unnecessary lubricant changes and minimise disruption to generation. Sampling frequency and test selection should reflect equipment criticality, operating conditions and manufacturer guidance.
More technical insights

Hydropower Inverter Drive Maintenance
Why preventative servicing of variable speed drives is essential for reliable turbine operation
Read insight
Archimedes Screw Bearing Replacement
Planning bearing renewal before unexpected turbine failure
Read insight
Hydraulic Accumulator Maintenance
Preventing hydraulic control faults through inspection and planned replacement
Read insight
Keep your hydropower assets running reliably
Contact Hydro Maintain to discuss routine servicing, oil and grease analysis, and preventative maintenance support for hydropower installations throughout the UK.